Solution

During recovery from various disasters (such as hardware failure, host system compromise, and others), it may become necessary to re-setup PVC node from scratch. Use the following steps to perform this procedure in the POA environment:

  1. List properties of the PVC hardware node registered in the POA database (let's say node's ID in POA is 31):

    plesk=> select * from hw_nodes where host_id=31;
    Expanded display is on.
    -[ RECORD 1 ]----+-------------------------------------
    host_id          | 31
    agent_username   | root
    agent_passwd     | {PEMBF}zlQXVFcVn/Ekcscjnfy1bA==
    agent_ip         | 010.010.010.010
    vz_ver_id        | 1
    slm_support      | 1
    hw_state         | a
    access_type      | p
    migrations_limit | 10
    last_check_time  | 2011-11-09 00:00:00+06
    ves_num          | 6
    is_service       | 1
    treport_task_id  | 0
    eid              | 0b412480-102d-5147-80f4-d71dcc4d9665
    protocol         | tcp
    lic_status       | a
    architecture     | x86_64
    logdir           |
    
  2. Set up the physical box; assign the same IP address; and install the OS suitable for the forthcoming PVC installation. Set up the same administrative account/password.

  3. Install the same version of PVC that you previously used. Follow solution from article:

    112006 -- How to install a specific version of Parallels Containers for Linux.

  4. Install compatible PVA Agent version according to the following article:

    112297 -- How to Install/Reinstall/Upgrade PVA 4.6 Agent to a PVC 4.6 HW Node on Redhat/CentOS 4.x

  5. Identify EID of the new PVC installation:

    111205 -- How to find out Parallels Virtuozzo Containers node EID?

  6. Update EID registered in POA database for the PVC hardware node:

    plesk=> update hw_nodes set eid='f7e1954b-c98e-4d94-aae1-0e61e0dfe480' where host_id=31;
    

Search words:

vzpp

disaster

reinstall

hardware node




64cafed7cc15bceb3b240d8c2f92dce3 909d99074e442b52ce54cc7b31cf065d caea8340e2d186a540518d08602aa065 2897d76d56d2010f4e3a28f864d69223 ca05eaf5b843fbd53589c90d7228a6df de15ebe36a547439f84e5981418f36c7 bf1c3a170005eae151f49ba2720abde9 bb8d08f557ff7e4b314b6bbaa846b034

FEEDBACK
Was this article helpful?
Tell us how we may improve it.
Yes No
 
 
 
 
 
 
Desktop Virtualization
- Parallels Desktop 9 for Mac
- Parallels Transporter
- Parallels Desktop Switch to Mac Edition
- Parallels Desktop for Mac Enterprise Edition
- Parallels Management-Mac for Microsoft SCCM
Server Virtualization
- Parallels Cloud Server
- Parallels Containers for Windows 6.0 Beta
- Parallels Virtuozzo Containers
Automation
- Parallels Automation
- Parallels Automation for Cloud Infrastructure
- Parallels Business Automation Standard
- Parallels Virtual Automation
- Parallels Plesk Panel Suite
- Web Presence Builder
- Parallels Plesk Automation
- Parallels Small Business Panel
- Value-added Services for Hosters
- Parallels Partner Storefront
Services & Resources
- Cloud Acceleration Services
- Professional Services
- Support Services
- Training & Certification